Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
HAH3DR 900-S07/SP1TRANSDUCER LEM USA Inc. |
0 |
|
![]() Datasheet |
HAH3DR | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 900A | 1 | Ratiometric, Voltage | 2.22mV/A | DC ~ 40kHz | ±1% | - | 4.75V ~ 5.25V | 6µs | 60mA | -40°C ~ 125°C | - | - | Unidirectional | Chassis Mount | - |
![]() |
HAT 1000-S/SP1TRANSDUCER LEM USA Inc. |
0 |
|
- |
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
LT 308-S7/SP8TRANSDUCER LEM USA Inc. |
0 |
|
- |
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
LA 55-P/SP11SENSORS LEM USA Inc. |
0 |
|
- |
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
LF 210-S/SP3TRANSDUCER LEM USA Inc. |
0 |
|
![]() Datasheet |
LF | Module, Single Pass Through | Bulk | Active | AC/DC | Closed Loop | 100A | 1 | Current | 1mA/A | DC ~ 100kHz | ±0.05% | ±0.2% | ±15.75V | 500ns | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
![]() |
LA 200-P/SP12SENSOR CURRENT HALL 200A AC/DC LEM USA Inc. |
0 |
|
- |
* | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
AT 10 B5TRANSDUCER LEM USA Inc. |
0 |
|
![]() Datasheet |
AT | Module, Single Pass Through | Bulk | Active | AC | Current Transducer | 10A | 1 | Voltage | - | 50Hz/60Hz | ±0.5% | ±1.5% | - | 300ms | - | -20°C ~ 60°C | - | - | - | Chassis Mount | - |
![]() |
LF 205-P/SP1TRANSDUCER LEM USA Inc. |
0 |
|
- |
LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 200A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.5% | ±12V ~ 15V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
![]() |
HTA 500-S/SP7TRANSDUCER LEM USA Inc. |
0 |
|
- |
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
HTA 200-SSENSOR CURR 200A -/+15V MOD LEM USA Inc. |
0 |
|
- |
* | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |